Use Of Multi-modality Imaging Techniques To Optimize Operative Strategy In Iatrogenic Ascending Aortic Dissection
Dong H. Lee, MD, Mortiz C. Wyler von Ballmoos, MD, PhD, MPH, Mahesh K. Ramchandani, MD.
Houston Methodist Hospital, Houston, TX, USA.
Objective:
Iatrogenic ascending aortic dissection after aortic cannulation for open cardiac procedure is a rare complication. We present our intraoperative, multi-modality imaging algorithm during iatrogenic aortic dissection to decide the optimal cannulation and repair strategy.
Method:
Shortly after arterial cannulation during ascending aortic aneurysm repair, expanding aortic hematoma was seen. Trans-esophageal echocardiogram (TEE), perfusion pressure, and cerebral oximetry were used to confirm adequate perfusion to the distal aorta and the brain.
Result:
First, a dissection was confirmed by TEE. Using color doppler imaging and perfusion pressure, antegrade flow in the true lumen was demonstrated. The absence of a reentry tear was ruled out by the same method. Symmetrical perfusion to the brain was confirmed with cerebral oximetry. Subsequently, hypothermic circulatory arrest was induced without the need for alternative arterial cannulation. A Bentall procedure was performed.
Conclusion:
TEE and cerebral oximetry allowed a rapid assessment of adequate distal perfusion to vital organs. Cerebral oximetry is an inexpensive and readily available adjunct modality that can aid in the evaluation of cerebral perfusion. Although not utilized in this case, addition of transcranial doppler to quantify symmetrical flow in the middle cerebral arteries may be beneficial in the future cases.
Back to 2018 Display Posters