Sternal Dehiscence: Management Using Modification Of Robichek Weave Using Rigid Plate Fixation
Keith B. Allen, A. Michael Borkon, Sanjeev Aggarwal, J. Russell Davis, Alex F. Pak, Eric Thompson, Jessica Heimes.
St. Luke's Mid America Heart Institute, Kansas City, MO, USA.
BACKGROUND: Sternotomy dehiscence presents reconstruction challenges particularly in the presence of multiple transverse fractures created by wire pull through. Sternal reconstruction using rigid plate fixation may offer an effective therapy to avoid more radical reconstructions or muscle flaps.
METHODS: Between July 2012 and October 2017 15 patients with sternal dehiscence and multiple transverse fractures (7 sterile and 8 infected) following primary closure with sternal wires were managed with a modification of the Robichek weave incorporating rigid plate fixation. Four and eight-hole titanium linear plates (ZimmerBiomet, Jacksonville, FL) were placed parallel to the sternotomy to bridge and stabilize the transverse sternal fractures. Plates were positioned so that appropriate length self-drilling cancellous screws could be placed to engage healthy bone and also ensure bi-cortical engagement of the sternal tables. Single or double wires were placed around the linear plates allowing the sternal halves to be reduced with the linear plates preventing wire pull through (Figure 1A). When indicated, additional plates were used to bridge the sternal halves and provide complete rigid fixation (Figure 1B and 1C). In the presence of sterile dehiscence, the wound was closed primarily. In infected cases, attempts were made to close the pectoral’s fascia and wound vac therapy was initiated.
RESULTS: All 15 patients were effectively treated without the need for sternectomy or muscle flap. An average of six plates (range 4-7) was used in each patient. Two patients with initial infection healed their bone but developed chronic sinus tracts that required further debridement and hardware removal. Patient demographics predisposing to sternal dehiscence included severe COPD (5), morbid obesity (8), renal failure (1) and immunosuppression following cardiac transplantation (1). No patient developed re-dehiscence during follow up (range 3-60 months).
CONCLUSION: Sternal dehiscence, particularly involving transverse fractures secondary to wire pull through, can be difficult to stabilize and rewire successfully. The addition of rigid linear plates to stabilize the transverse fractures and to serve as a barrier to prevent wire pull through during sternal reduction may provide important mechanical advantages over a traditional Robichek weave with wires alone.
LEGEND:4 and 8-hole linear plates placed parallel to the sternotomy incision bridge to stabilized transverse fractures on left sternal half (A) and prevent new wires from pulling through (patient 1). Lower sternum (B) successfully stabilized (patient 11) with rigid plate fixation combined with double wires (C).
Back to 2018 Display Posters