International Society For Minimally Invasive Cardiothoracic Surgery

Back to 2018 Display Posters


Bicuspid Aortic Valve In Transcatheter And Surgical Aortic Valve Replacement
LING ZHU, Yi Chuan Tham, Le Wen Tan, See Hooi Ewe, Kay Woon Ho, Jia Lin Soon.
National Heart Centre Singapore, Singapore, Singapore.

Objective: Patients with Bicuspid Aortic Valve (BAV) are not at increased procedural risk for Surgical Aortic Valve Replacement (SAVR) if their aorta is not dilated. Transcatheter Aortic Valve Replacement (TAVR) is increasingly being offered to patients with BAV. The adverse consequences associated with paravalvular leaks after TAVR however remains a concern. Methods: A prospective review of our institutional database was performed. Between October 2011 and December 2017, 257 consecutive aortic valve procedures were performed by a single operator/team. Patients who underwent concomitant operations were also included (STS scores were not available for triple valve surgery patients). Twenty six BAV patients (10.1%) were compared with 231 non-BAV patients. Results: BAV patients showed a trend to be younger: 69±16 years vs. 74±10 years old (p=0.157). There were no statistically significant differences between BAV and non-BAV patients with regards to gender (50% BAV patients), prevalence of diabetes (26.9% BAV), or past coronary bypass surgery (3.8% BAV), bioprosthesis use (84.6% BAV), body surface area, and implanted prosthesis size. The STS predicted risk of mortality were comparable: 4.8±5.6% (BAV) vs 4.6±3.6% (Non-BAV), (p=0.839). The observed 30-day mortality were respectively: 3.8% for BAV patients (1/26) compared to 5.6% (13/231) in non-BAV patients. BAV patients were however more likely to have underwent SAVR: 14/85 (16.5%) of SAVR patients, compared to 12/172 (7.0%) of TAVR patients (p=0.018). Hypertension was also less common in BAV patients: 50% vs 78.4% (p=0.003). Statistically significant improvement in left ventricular ejection fraction (LVEF) (54.7±13.4% to 58.1±10.1%, p=0.003), and left ventricular mass regression were observed at 1-year in 116 paired-samples (p<0.0001). One-year prosthesis indexed aortic valve orifice area (1.6±0.5cm2 BAV), mean pressure gradient (13.8±7.6mmHg BAV), and LVEF (56.9±8.7% BAV) were comparable between both BAV and non-BAV groups. Conclusion: SAVR remains the gold standard treatment for majority of BAV patients, with excellent clinical and prosthetic hemodynamic outcomes. Selected BAV patients may benefit from TAVR, but residual paravalvular leak remains a concern in younger patients.


Back to 2018 Display Posters