Processing of Residual Cardiopulmonary Bypass Volume Reduced Postoperative Blood Loss In Minimally Invasive Cardiac Surgery
Ryosuke Muraki, Toshinori Totsugawa, Kosuke Nakajima, Tomoya Oshita, Masahisa Arimichi, Kazuyuki Nagata, Taichi Sakaguchi.
The Sakakibara Heart Institute of Okayama, Okayama, Japan.
BACKGROUND: Several reports have shown that processing of residual blood remaining in the cardiopulmonary bypass (CPB) circuit using a cell salvage device had positive effects on hemostasis in patients undergoing conventional open heart surgery. However, its efficacy for minimally invasive cardiac surgery (MICS) has not been clarified. The aim of this study is to evaluate the effect of transfusion of the processed residual blood (PRB) on hemostasis in MICS cases.METHODS: Between October 2015 and September 2017, consecutive 50 patients who underwent isolated aortic valve replacement via a right mini-thoracotomy were enrolled into the present study. Patients were divided into two groups: 25 patients who were re-transfused with unprocessed residual volumes (Control group); and 25 patients who were transfused with PRB (CS group). The residual volume of CPB circuit was processed using a cell salvage device. Clinical outcomes and coagulation parameters were compared between the two groups. RESULTS: Mean residual volume before processing was 580±36 ml. There were no significant differences in patient characteristics, operation time, and transfusion rate of packed red blood cells. The amount of intraoperative bleeding was similar between the two groups (CS group, 242±3 ml vs Control group, 259±46 ml; p=0.12). No significant differences were found in platelet count and serum fibrinogen level; however, the amount of postoperative blood loss in CS group was significantly lower than that in Control group at 6 hours (78±31 vs 123±47 ml, p=0.0007) and 12 hours (140±71 vs 186±140ml, p=0.03) after surgery. Furthermore, the serum D-dimer level of CS group was significantly lower than that in Control group (0.9±0.9 vs 2.7±4.5, p=0.008) and postoperative transfusion rate of fresh frozen plasma was significantly lower in CS group (0 vs 24%, p=0.02).CONCLUSIONS: Transfusion of processed CPB volume reduced postoperative blood loss in patients undergoing MICS.
Back to 2018 Display Posters