Mitral valve replacement technology through anterior right minithoracotomy.
Berik Bolatbekov, Dr., Ikrom Mukhamedov, Dr., Aiman Issakova, Dr., Almas Begdildaev, Dr., Zafar Rozbaev, Dr., Aliya Azimzhanova, Dr., Seithan Dzhoshibaev, Prof.MD,.
Research clinical center of cardiac surgery and transplantation, Taraz, Kazakhstan.

Mitral heart valve replacement technology through anterior right minithoracotomy.
Objective. Median sternotomy associates with high rate of complications as: bleeding, infection of tissues, divergence of sternum, mediastenitis, mortality and etc. Analysis of clinical material was the reason for further study to develop and implement minimally invasive approaches as an alternative to the standard sternotomy. In this study we assessed the effectiveness of right anterior minithoracotomy technologies in mitral valve replacement.
Materials and methods. The Study included 1739 patients operated in the period from March 2009 till December 2014. All patients were divided into 2 groups: Group 1 (MICS) mitral valve replacement were made by right-anterior minithoracotomy 55 (4%) patients, group 2 (control) includes patients operated by median sternotomy-1684 (96%) cases.
The minimal invasive approaches were determined by chest X-ray in frontal projection taking into account localization of the aortic root and diaphragm-pericardial angle with. For three patients with thoracotomy approach we performed RFA of the pulmonary veins. They were discharged with sinus rhythm and without esophageal and bleeding complications.
Results. The total operation time in MICS and control groups were respectively: 187 ± 21 vs 231 ± 34 min, p <0.0001. Average time of cardiopulmonary bypass and aortic cross-clamping in both groups did not revealed any statistical differences. Also We found 2.3 times more waste of time for hemostasis in the control group than in MICS group. In the early postoperative period in MICS group blood losses by drainages were 130 ± 29 ml and in Control group 370 ± 41 mL (p <0.0001). Also we revealed shorter time of mechanical ventilation (93 ± 21 vs 114 ± 41 hours, p <0.0001), more earlier discharge from hospital (6,8 ± 1,1 vs 12 ± 2,8 days, p <0.0001), reduction of surgical wound infection and festering.
Conclusions. Right-anterior minithoracotomy technology is an effective alternative to classic sternotomy with benefits as: preserved anatomical integrity of the chest carcasses, an earlier extubation, reduced blood losses, decreased probabilities of infectious wound complications, early discharging and a good cosmetic effect.