Back to 2015 Annual Meeting Posters
Does ministernotomy improve postoperative outcome in aortic valve operation? A real-world multicenter study
KHALIL FATTOUCH, MD1, PIETRO DIOGUARDI, MD1, MAURO DEL GIGLIO, MD2, ALBERTO ALBERTINI, MD3, RENATO GREGORINI, MD4, ROBERTO COPPOLA, MD5, GIUSEPPE NASSO, MD6, GIUSEPPE SPEZIALE, MD6.
1GVM Care and research - Maria Eleonora Hospital, Palermo, Italy, 2GVM Care and Research - Maria Cecilia Hospital, cotignola, Italy, 3GVM Care and research - Maria Cecilia Hospital, Cotignola, Italy, 4GVM Care and research - Citta' di Lecce Hospital, Lecce, Italy, 5GVM Care and research - ICLAS - Istituto Clinico Ligure di Alta Specialità, RAPALLO, Italy, 6GVM Care and research - Anthea Hospital, Bari, Italy.
OBJECTIVE: Aortic valve replacement (AVR) has been performed through a standard median sternotomy for over 40 years. The minimally invasive revolution affecting general surgery in the late 1980s also influenced cardiac surgery resulting in the emergence of several minimal access approaches for AVR. Currently, the upper partial sternotomy with unilateral J-shaped extension to the right through the fourth intercostal space is the most popular minimal access approach.
We report a real world multicenter clinical experience of GVM Care and Research hospitals with a approach for AVR via ministernotomy.
METHODS: Patients data were collected from 9 hospitals and prospectively entered in the electronic database. After obtaining the institutional review board approval, patient’s data were analyzed retrospectively. Patients with concomitant coronary artery disease were excluded from the analysis. AVR via ministernotomy was performed in 872 patients between 01/2010 and 12/2013. Intra- and postoperative data including cross clamp time, cardiopulmonary bypass time, mortality, stroke, pacemaker implantation, re-operation for bleeding, need for blood transfusion, ventilation time, ICU and hospital stay time, wound infection, sternal dehiscence and 30 day mortality and morbidity were collected.
RESULTS: Mean patients age was 71.9 +/−11.5 years and 46.2% were female. Median euroscore was 6.48 +/−2.5. Minimal-access AVR could be performed with upper partial sternotomy in all patients. Conversion to full sternotomy was not found in this series. Aortic cross-clamping time was 62.9 +/−24.6 min, cardiopulmonary bypass time 77.6+/−33.01 min. Re-operation for bleeding had to be performed in 31 cases (3.6%). There were 3 strokes and pacemaker implantations needed in 10 patients. Mean ventilation time was 4.5 h, ICU stay time was 3.97 days and mean length of hospital stay was 11 days. Hospital mortality was 2.3% and 18 (2.1%) sternal dehiscence or wound infection was observed. Echocardiographic contrl was performed in all patients in operating room and at hospital discharge; paravalvular leak wasn’t observed.
CONCLUSIONS: Minimal-access AVR via ministernotomy can be performed safely, even in high risk patient cohort without adding additional operative risk compared to conventional AVR. By avoidance of large skin incisions this approach combines excellent cosmetic results with fast surgery time and excellent postoperative recovery.
Back to 2015 Annual Meeting Posters




