ISMICS 15 ISMICS 15 ISMICS 15
Exhibitors & Sponsors
 
 
Past Meetings
Future Meetings

Back to 2015 Annual Meeting Posters


Aortic Valve Replacement Through Manubrium-limited Sternotomy is Safe and Reduces Blood Loss
Vivek Srivastava, Ignacio Bibiloni, Tracey Smailes, Andrew Owens, Andrew Goodwin, Enoch Akowuah.
James Cook University Hospital, Middlesbrough, United Kingdom.

Background: To evaluate outcomes for aortic valve replacement (AVR) with manubrium-limited (mini) against conventional median sternotomy.
Methods: First-time non-endocarditic isolated AVRs (n=279) between November 2011 and February 2014 were identified from departmental database and divided into ‘conventional’ and ‘mini’ groups. Preoperative characteristics and postoperative outcomes of the two groups were compared using Chi- square test for categorical variables and Students t-test or Mann-Whitney U test for continuous variables depending on normality (Shapiro-Wilk test).
Results: (Table 1).‘Conventional’ group (n=128) and ‘mini’ group (n=151) had comparable preoperative characteristics except a significantly higher incidence of hypertension, extracardiac arteriopathy and history of neurological dysfunction in ‘mini’ group. Overall risk profile was similar (Additive EuroSCORE I 6.6 ± 2.2 vs. 6.1 ± 2.4, p=0.83; EuroSCORE II 2.4 vs. 2.3, p=0.48). ‘Mini’ group had significantly longer CPB, cross-clamp and overall operative times. Postoperative blood loss was significantly less with ‘mini’ approach (445.2 ml vs. 333.4 ml, p=0.000). Transfusion rates for RBC (p=0.11), FFP (p=0.02) and platelets (p=0.11) was higher in the conventional group. Reoperation rates for bleeding and valvular problems were similar. Other major complications (AF, stroke, renal failure, wound infections, pacemakers) had similar incidence. There was one death in each group. Postoperative stay was comparable with median 7 days (mini) vs. 6 days (conventional), p =0.523. On follow-up, more than mild paravalular leak was seen in 3 patients (mini) and 1 patient (conventional).
Conclusions: AVR with manubrium-limited approach achieves equivalent outcomes as full median sternotomy with the added advantage of less blood loss and transfusion requirements.
Table 1: Manubrium-limited vs. conventional sternotomy
conv (n=128)mini (n=151)p value
Preoperative characteristics
mean age (yrs)70.9 ± 10.770.0 ± 11.90.67
females57 (44.5%)67 (44.4%)0.98
BMI28.9 ± 6.229.8 ± 6.30.12
Hypertension76 (59.4%)112 (74.2%)0.01
Pulmonary disease22 (17.2%)37 (24.5%)0.14
Diabetes no DM107 (83.6%)127 (84.1%)0.64
diet controlled4 (3.1%)5 (3.3%)
tab controlled14 (10.9%)12 (7.9%)
insulin3 (2.3%)7 (4.6%)
Extracardiac arteriopathy1 (0.8%)9 (6.0%)0.02
Neurological dysfunction9 (7%)24 (15.9%)0.02
Renal dysfunction none125 (97.7%)150 (99.3%)0.49
non-dialysis renal imp.1 (0.8%)0
dialysis for ARF1 (0.8%)0
dialysis for CRF1 (0.8%)1 (0.7%)
EF good (>50 %)107 (83.6%)118 (78.1%)0.25
moderate (30-50%)15 (11.7%)22 (14.6%)
poor (20-29%)6 (4.7%)7 (4.6%)
very poor (<20%)04 (2.6%)
Add EuroSCORE I6.6 ± 2.26.1 ± 2.40.83
EuroSCORE II2.42.30.48
Operative details
Valve bioprosthesis107 (83.6%)115 (76.2%)0.13
mechanical21 (16.4%)36 (23.8%)
cross clamp time (min.)61.2 ± 16.566.8 ± 21.50.010
CPB time (min.)78.9 ± 23.288.6 ± 33.40.014
operative time (min.)163.9 ± 38.3194.2 ± 56.00.000
conversions-10-
Postoperative outcomes
blood loss (ml)445.2333.40.000
reoperation for bleeding1 (0.8%)7 (4.6%)0.055
reoperation for valve problems1 (0.8%)3 (2%)0.4
No. of pts. transfused RBC47 (36.7%)42 (27.8%)0.11
FFP39 (30.5%)28 (18.5%)0.02
Platelets25 (19.5%)19 (12.6%)0.11
atrial fibrillation44 (34.4%)68 (45%)0.07
new stroke00-
new renal failure4 (3.1%)8 (5.3%)0.37
PPM6 (4.7%)7 (4.6%)0.98
deep sternal wound infection1 (0.8%)1 (0.7%)0.91
deaths1 (0.8%)1 (0.7%)0.91
More than mild paravalvular leak1 (0.8%)3 (2%)0.4
Median postop stay (IQR) - days6 days (5-8)7 days (5-10)0.523


Back to 2015 Annual Meeting Posters