Alternative Technique for Cardioplegia Delivery in Totally Endoscopic Robotic Intracardiac Surgery
Ishikawa Norihiko, Go Watanabe, Shigeyuki Tomita, Shojiro Yamaguchi, Ryuta Kiuchi, Hroshi Ohtake, Kenji Kawachi.
NewHeart Watanabe Institute, Tokyo, Japan.

OBJECTIVE: The optimal technique for antegrade cardioplegia delivery during totally endoscopic robotic surgery is still evolving. Cardioplegia delivery with endovascular balloon clamping of the aorta is commonly used but this method has several disadvantages and may lead to serious complications. We describe a novel cardioplegia delivery procedure for totally endoscopic intracardiac surgeries.
METHODS: With the help of surgical robot, double purse-string elastic sutures orienting at 180 to each other were placed on the aorta around the planned site of cardioplegia cannula insertion. The 2 ends of 1 elastic suture were clipped together using robotic clips, and both sutures were clipped in the same manner. An antegrade cardioplegia needle was passed through the chest wall directly. Inside the thoracic cavity, with the help of robotic instruments, an antegrade cardioplegia cannula was inserted through the middle of the purse-string sutures into the ascending aorta. Then, the transthoracic aortic cross-clamp together with blood cardioplegia delivered intermittently through the antegrade cardioplegia cannula maintained cardiac arrest and provided myocardial protection. After intracardiac procedure was completed, removal of air through the antegrade cardioplegia cannula, a hot shot dose of cardioplegia, and removal of the cross-clamp was performed. Before weaning from cardiopulmonary bypass, the antegrade cardioplegia cannula was removed and the elastic purse-string sutures were drawn together by sliding the clips that were placed beforehand. Closure by the purse-string sutures temporarily stopped bleeding from the cannula hole. An additional 4-0 proline suture was placed to ensure hemostasis. Finally the proline suture was tied. There was no bleeding from the cardioplegia site.
RESULTS: This technique was used in 137 consecutive cases during robotic-assisted, totally endoscopic cardiac procedures (65 ASD closures and 72 mitral valve repairs). There was no postoperative bleeding from the cardioplegia cannula site and no complications related to this novel method.
CONCLUSIONS: This technique can perfomed via port without the need for thoracotomy, and is safe and reliable, permits simple cardioplegic arrest, and prevents complications related to endovascular balloon clamping during robot-assisted intracardiac surgery.