Back to 2015 Annual Meeting Posters
Robotic Cardiac Surgery: 7-year Single-center Follow-up Results
Changqing Gao, Ming Yang, Huajun Zhang, Cangsong Xiao, Yang Wu, Gang Wang, Yao Wang, Jiali Wang.
PLA General Hospital, Beijing, China.
OBJECTIVE: This study aims to summarize the experience of 700 cases of robotic cardiac surgery with 7-year follow-up results revealed.
METHODS: A total of 700 patients underwent robotic cardiac surgery using da Vinci Surgical System (Intuitive Surgical, USA) from January 2007 to November 2014 in our hospital. There were 429 male and 271 female with a median age of 49 years (range, 11 to 80 years). With left port approach, 240 cases of coronary artery bypass graft were completed, including totally endoscopic coronary artery bypass graft on beating heart (BH-TECAB, n=100) and minimally invasive direct coronary artery bypass graft on beating heart (MIDCAB, n=140). The patients with multiple-vessels coronary artery disease received hybrid coronary bypass revascularization in separate session (n=35). The graft patency was followed with CT angiogram (CTA) or coronary angiography up to 5 years postoperatively. With right port approach, atrial septal defect repair on arrest or beating heart (n=180), ventricular septal defect repair (n=30), mitral valve repair (n=100) or replacement (n=50), atrial myxoma resection (n=60), were completed. Patients were followed up at 6 month, 1 year, 3 years and 5 years postoperatively with clinical and echocardiographic status assessed.
RESULTS: All cases were performed successfully and no operative mortality was observed. Operating time was shortened significantly for all procedures with significant learning curves. One case was converted to median sternotomy due to aortic perforation. One patient had hemolysis after mitral valve repair. Two patients scheduled for BH-TECAB had conversion to minithoracotomy. During the follow-up length of 40.9 ±16.5 months (range, 1 to 86 months), no residual shunt, peri-valvular leaks, recurrence of tumor was noticed. Surgical outcomes at day 30 after surgery were excellent. All patient who underwent robotic coronary surgery were discharged with 100% graft patency. The graft patency was 98.1% at 1 year and 97.8% at 2 years postoperatively. No death or MACE was reported in the follow-up period.
CONCLUSIONS: Our study shows that robotic heart surgery follow-up results are excellent for a broad spectrum of patients. We believe that robotic cardiac surgery is truly minimally invasive cardiac surgery in the future.
Back to 2015 Annual Meeting Posters