Is There a Role for Diagonal Coronary Artery Stenting in Patients Undergoing Robotic Coronary Artery Bypass Graft Surgery?
Jeevan Nagendran1, Jorge Catrip2, Stephanie Fox2, Michael Chu2, Patrick Teefy2, Kumar Sridhar2, Pantelis Diamantouros2, Bob Kiaii2.
1University of Western Ontario, Edmonton, AB, Canada, 2University of Western Ontario, London, ON, Canada.
Introduction: Hybrid coronary artery revascularization is defined as the combination of left internal thoracic artery (LITA) to left anterior descending (LAD) artery grafting and percutaneous coronary intervention (PCI) of ≥ 1 non-LAD coronary arteries. The patency of the diagonal artery graft in bifurcating lesions of the LAD and diagonal artery is always questionable due to competition of flow from the LITA graft. Recently, we and others have shown that a single-stage hybrid revascularization strategy appears to have acceptable 6-month results. However, the efficacy of diagonal coronary artery stenting in patients undergoing robotic LITA-to-LAD anastomosis is not well defined. The objective of this study was to assess graft and stent patency in a single-stage hybrid revascularization with LITA-to-LAD anastomosis and PCI to a diagonal coronary artery.
Methods: From 2004 to 2014, a total of 25 patients consented to robotic-assisted LITA harvesting and a small left anterior thoracotomy for off-pump coronary artery bypass anastomosis onto the LAD along with concomitant PCI to the diagonal coronary artery. This was followed immediately by PCI to a diagonal coronary artery in the same fluoroscopy-equipped hybrid operating room.
Results: There were a total of 25 (66 ± 11 years; 32% female) patients undergoing robotic-assisted LITA harvesting and a small left anterior thoracotomy for off-pump coronary artery bypass anastomosis onto the LAD and PCI to the diagonal coronary artery. Pre-operative characteristics of these patients included 8% with a grade 3 or 4 left ventricle, 16% with a recent MI, and 92% with CCS III/IV symptoms. There were no deaths, one patient required an intra-aortic balloon pump, and one patient required re-operation for bleeding. The average ICU stay was 1.1 ± 0.53 days, and the average hospital stay was 4.6 ± 2.4 days. Fitzgibbon Grade A LITA-to-LAD patency at 6-month follow-up was 100%. As well, at 6-month follow-up the DES to the diagonal coronary artery had a patency rate of 96%.
Conclusion: Single-stage hybrid revascularization strategy for bifurcating lesions of the LAD and diagonal coronary arteries with LITA-to-LAD anastomosis and PCI to a diagonal coronary artery appears to have acceptable clinical results with excellent 6-month angiographic patency results.
Back to 2015 Annual Meeting Posters