ISMICS 15 ISMICS 15 ISMICS 15
Exhibitors & Sponsors
 
 
Past Meetings
Future Meetings

Back to 2015 Annual Meeting Posters


External Vein Support in Coronary Artery Bypass Grafting - Early Results from the eMESH I Trial. Work in Progress
Lars Englberger1, John D. Puskas2, Robert W. Emery3.
1University Hospital Berne, Berne, Switzerland, 2Icahn School of Medicine at Month Sinai, New York, NY, USA, 3St Joseph's Hospital, St Paul, MN, USA.

OBJECTIVE:
The eMESH I Trial is a multi-center, international FDA feasibility study. The eSVS Mesh (Kips Bay Medical, Inc.) is a circular weft knit, nitinol wire support sleeve that is deployed over the external surface of saphenous vein grafts (SVG) in coronary artery bypass surgery (CAB). The eSVS Mesh may improve long-term patency of SVG by reducing intimal hyperplasia.
METHODS:
From March 2013 through October 2014, 64 patients (age 68+/-9 years, 81% male) were enrolled at 7 European and 4 US centers. The study included a randomized arm (N=51) and a single use arm (N=13). In the randomized cohort, two veins were randomized to either mesh supported or unsupported and the coronary targets were randomized to the Right (RCA) or Circumflex artery (CCX), the other being unsupported. In the single use group, one vein received mesh support and was targeted to either the RCA or CCX. Angiography was completed at 6 months.
RESULTS:
The mesh was successfully deployed in all cases and there were no device related complications. There was no operative mortality. Angiography at six month was completed in 40 patients showing statistically different patency between mesh supported and unsupported grafts (67% vs 91%, p=0.01). Due to the lower patency of the mesh-supported grafts, with unanimous center approval, the implant technique was modified after July 2014 to discontinue the use of biologic sealant and to not include the mesh in the suture line of either proximal or distal anastomoses. Angiography in 15 patients enrolled after this date will be completed by May 2015 and compared to the data from patients using the previously recommended technique.
CONCLUSIONS:
With the change in implant protocol to make the procedure more akin to routine CAB, improvement in the patency of mesh supported SVG is expected. The aim of this “work in progress” is to find the optimal implant technique to design a large pivotal trial focusing on clinical efficacy of the device.


Back to 2015 Annual Meeting Posters