ISMICS 15 ISMICS 15 ISMICS 15
Exhibitors & Sponsors
 
 
Past Meetings
Future Meetings

Back to 2015 Annual Meeting Posters


Midterm outcomes of Thoracoscopic Ablation of Atrial Fibrillation using Dallas Lesion set
Ali Khoynezhad.
Cedars-Sinai Medical Center, Los Angeles, CA, USA.

OBJECTIVE: Atrial fibrillation (AF) is the most common sustained arrhythmia and is associated with a nearly five-fold increased risk for stroke as well as over two-fold increased risk of death. For symptomatic drug-refractory AF, percutaneous ablation has been used with varying success and possible incomplete ablation lines. AF is often combined with structural heart disease, but patients with lone AF are optimal candidates for the endoscopic ablation treatment. We analyzed our data in endoscopically performed ablation of atrial fibrillation using Dallas Lesion set.
METHODS: From January 2012 through January 2014, a total of 48 symptomatic and drug-refractory patients with lone atrial fibrillation underwent a thoracoscopic epicardial ablation using the bipolar radiofrequency clamp (AtriCure Inc.). 27 of these patients were performed using Dallas lesion sets on the beating heart. All of them had persistent long-standing AF. Epicardial ablation was performed on 19 men (70%) and 8 women (30%), with a mean age of 64 (range 47 to 82) years. After the ablation, in all patients entrance and exit block was confirmed and the left atrial appendage was excluded.
RESULTS: There were no hospital stroke, myocardial infarction or operative mortality. In two patients fem-fem cardiopulmonary bypass was used to fix a laceration of the left atrial appendage and left atrium. The follow-up was completed in 91% with a mean length of 13 months with a freedom of AF in 90%. The heart rhythm was documented in all of them besides 7 patients with a holder-ECG with duration of at least of 7-days. In 2 patients the postoperatively persistent AF or flutter was treated with radiofrequency ablation. Pacemaker implantation was done in 3 patients (10%) due to bradycardia (n=2) and sick-sinus syndrome (n=1). There were 2 late deaths (7%) one due to pulmonary embolism (PE) and non-AF related stroke.
CONCLUSIONS: Thoracoscopic radiofrequency ablation using Dallas lesion set on the beating heart for treatment of atrial fibrillation is technical feasible, and achieves high success rates with low procedure-related morbidity. Collaboration with electrophysiology colleagues is critical for optimal patient care.


Back to 2015 Annual Meeting Posters
© 2026 International Society for Minimally Invasive Cardiothoracic Surgery. All Rights Reserved. Read Privacy Policy.