Back to 2015 Annual Meeting Posters
Minimally Circulatory-Assisted On-Pump Beating Coronary Artery Bypass Grafting for Patients with High Risk of Hemodynamic Deterioration during Off-Pump Grafting
Tomohiro Mizuno, Kenji Sakai, Keiji Oi, Tsuyoshi Hachimaru, Tohru Makita, Kiyotoshi Oishi, Hirokuni Arai.
Tokyo Medical and Dental University, Graduate School of Medical and Dental Science, Tokyo, Japan.
OBJECTIVE: While off-pump coronary artery bypass grafting (OPCAB) is beneficial in high-risk patients, it is sometimes difficult or dangerous to perform in patients with hemodynamic instability. In such patients, we performed minimally circulatory-assisted on-pump beating coronary artery bypass grafting (MICAB). The anastomotic procedure was completely identical to the OPCAB procedure while circulation was minimally assisted by a femoro-femoral bypass with percutaneous cardiopulmonary support, and pulsatile circulation was maintained at a systolic blood pressure of 100 mmHg with a systolic pulmonary arterial pressure of ≤ 30 mmHg during anastomosis.
METHODS: From September 2006 to March 2012, 37 patients underwent MICAB, comprising emergent or urgent MICAB in 28 patients for acute myocardial infarction (AMI) and elective MICAB in 9 patients with dilated left ventricle or small target vessels. The detail of the intra- and post-operative patients’ condition was evaluated and compared to those in OPCAB patients.
RESULTS: The minimum assist flow index (support flow/body surface area) during the anastomosis to the left anterior descending artery, left circumflex artery, and right coronary artery was 1.01 ± 0.41, 1.31 ± 0.52, and 1.14 ± 0.46 L/min/m2, respectively, in the 28 emergent or urgent MICAB patients, and 0.73 ± 0.12, 1.26 ± 0.41, and 1.24 ± 0.43 L/min/m2, respectively, in the 9 elective patients. The number of the distal bypass grafts was 3.2 ± 0.9 (range, 1-5 grafting), the complete revascularization rate was 94.6% and the acute patency rate was 98.9%. Intraoperative ventricular fibrillation occurred in 2 patients, but the circulation was maintained with quick temporary increase of the support flow. The postoperative values of serum creatine kinase MB in elective MICAB patients were comparable to those following OPCAB. The 30-day mortality was 2.7% (n = 1). There were no cerebrovascular complications or postoperative newly-occurring cases of renal failure.
CONCLUSIONS: In patients in whom it is difficult to performe OPCAB, MICAB is a safe alternative to OPCAB, especially in patients with AMI, providing benefits similar to those offered by OPCAB, including myocardial protection, renal protection, and benefits similar to those offered by conventional CABG including high complete revascularization and acute patency rates.
Back to 2015 Annual Meeting Posters