Back to 2015 Annual Meeting Posters
EPICARDIAL LEFT VENTRICULAR LEAD PLACEMENT IN MINIMALLY INVASIVE THORACIC SURGERY FOR CARDIAC RESYNCHRONIZATION THERAPY
andrea droghetti, Maria Caterina Bottoli, Michele Giovanardi, Patrizia Pepi, Giovanni Muriana, Albino Reggiani.
Carlo Poma Hospital, Mantua, Italy.
OBJECTIVE: The benefits of cardiac resynchronization therapy (CRT) for patients with heart failure are well established,
providing significant improvements in exercise tolerance, functional status and quality of life and reducing
hospitalization and mortality.
The standard transvenous approach for LV lead positioning presents some limitations and complications.
Several alternative techniques have been proposed: thoracotomy, video-assisted thoracoscopy, and robotic-assisted.
We applied a really minimally invasive videothoracoscopic technique (VTS) using three ports for the insertion of
left-ventricular screw-in electrode using the dedicated tool.
METHODS: Transvenous implantation of the left ventricular pacing lead failed in eighty-three patients (M: 51; F: 32;
mean age: 63.4 years) with heart failure (EF median 20%, NYHA 3±1, QRS 184 ±21 ms) meeting the
ACC/AHA guidelines for implantation of biventricular pacing. In right-lateral decubitus position and under
single-lung ventilation a pericardiotomy was made posterior to the phrenic nerve and an electrode was
screwed in by videothoracoscopic tool via three ports using camera. The lead was then guided subcutaneously to the pacemaker pocket.
RESULTS: Mean skin-to-skin operating time was 39 mins, no conversion to thoracotomy was necessary. All patients
were extubated in the operating room and came back to our division. Chest tube was removed after a mean
of 18 hours and the patients were discharged after a mean of 3.4 days. Postoperative pacing thresholds were
satisfactory in all cases and there was no lead dislocation. All patients had an improvement of their NYHA
function class,ejection fraction, quality of life and exercise tolerance. There was neither surgical major morbidity nor mortality.
CONCLUSIONS: Video-assisted thoracoscopy using three ports seems to be an excellent procedure for epicardial lead
implantation. This technique improves clinical outcome and LV performance without changes in pacing
parameters, with tolerable stress for patients.
| DATA | PRE-SURGERY | POST-SURGERY (6 MONTHS) | STATISTICAL SIGNIFICATIVITY |
| LEFT VENTRICULAR EJECTION FRACTION (%) | 26±6 | 42±10 | S (0.031) |
| LEFT VENTRICOLAR END-DIASTOLIC VOLUME (ML) | 202±52 | 130±28 | S (0.013) |
| IMPEDANCE (OHM) | 465±142 | 341±58 | S (0.014) |
| LEFT VENTRICULAR THRESOLD | 1.14±1 (INTRAOPERATIVE) | 1.19±0.5 | NS (0.5) |
Back to 2015 Annual Meeting Posters