ISMICS 15 ISMICS 15 ISMICS 15
Exhibitors & Sponsors
 
 
Past Meetings
Future Meetings

Back to 2015 Annual Meeting Posters


Intra-operative Quality Control of CABG using High Frequency Epicardial Ultrasound Imaging in combination with Transit Time Flow Measurement
Hirokuni Arai, Taiju Watanabe, Keiji Oi, Tomohiro Mizuno.
Tokyo Medical & Dental University, Tokyo, Japan.

OBJECTIVE:
High frequency epicardial ultrasound (ECUS) is a useful modality for intraoperative imaging. Since 2010, we introduced 15 MHz high frequency ECUS and have been investigating the efficacy of it as intraoperative validation in coronary artery bypass grafting (CABG).
METHODS: In CABG procedure, we directly scanned the coronary artery to decide the optimal anastomosis sites, strategized graft placement, and verified the anastomosis quality in addition to the routine use of transit time flow measurement (TTFM). TTFM was performed in every anastomosis. When flow, pulsatility index or diastolic filling was unsatisfactory, configuration of the anastomosis was precisely evaluated by ECUS. Then, the anastomosis was revised, if necessary. Early graft patency of past three years (off-pump CABG ratio of 93%) with combined intra-operative validation protocol of TTFM and ECUS was evaluated by either coronary angiogram or CT.
RESULTS: ECUS could provide more detailed information including the location of coronary artery, regional intraluminal calcified plaque and intra-myocardial coronary artery, avoiding unnecessary dissection or accidental injury of the right ventricle. With the precise images of intraluminal calcified plaque, we could make surgical decision for graft placement whether to perform on-lay patch grafting or not. Accidental dissection of the internal thoracic artery (ITA) was also easily detected and the anastomosis was revised when it happened. The early patency of each anastomotic site was LAD: 100%, Lcx: 97% and RCA: 100%, respectively. The early patency of each graft was LITA: 100%, RITA: 100%, radial artery: 95% and saphenous vein graft: 97%, respectively.
CONCLUSIONS: High frequency ECUS can easily be employed as a complementary quality-control modality to TTFM, leading to successful surgical decision making and improvement of the quality of CABG.