Back to 2015 Annual Meeting Posters
Transcatheter Valve-in-Valve Implantation for Degenerated Surgical Bioprostheses. Single center experience.
Vito Giovanni Ruggieri, Sana Chatti, Reda Belhaj Soulami, Amedeo Anselmi, Majid Harmouche, Dominique Boulmier, Herve Lebreton, Jean Philippe Verhoye.
Pontchaillou University Hospital, Rennes, France.
OBJECTIVE: Standard redo open heart surgery is the treatment of choice in case of bioprosthetic degeneration. However, elderly patients with associated comorbidities are at high surgical risk. Transcatheter valve-in-valve procedures represent an attractive option in this population. We report our first single-institution experience concerning valve-in-valve transcatheter procedure in patients with failing bioprosthetic heart valves.
METHODS: Among 450 transcatheter procedures performed in our institution from February 2009 to December 2014, 18 patients (aged 74,5±7,5 years) with failed bioprosthetic valves (16 aortic, 2 tricuspid) underwent valve-in-valve implantation. Two patients had previous Bentall operation and one young patient presented with massively calcified degenerated aortic homograft. The mean logistic EuroSCORE I was 25,3 ± 5,5 and the mean STS Score was 23,9 ± 4,6. Bioprostheses mode of failure was predominant stenosis (n=8; 44,4%), regurgitation (n=4; 22,2%) or mixed stenosis and regurgitation (n=6; 33,3%). The mean time since last valve replacement was 11,5±3,2 years (range 2,4 - 28 years).
RESULTS: Implanted devices included CoreValve (n=8) and Edwards SAPIEN (n=10). The main access route in aortic position was transfemoral (n=10; 62,5%), versus transapical (n=3) and transsubclavian (n=3) approaches. The procedural success was achieved in 100%. The mean aortic gradient decreased from 38,5±10,4 mmHg to 14,3±2,6 mmHg, and the reduction in the mean tricuspid gradient was 9,7 mmHg to 4 mmHg. No significant regurgitation was observed post-implantation. The mean length of hospital stay was 8 days (range 4-18 days). There was no in-hospital or 30-day mortality. Two non-valve-related late deaths occurred during the follow-up (mean 4,7 months; range 1-24 months). NYHA functional class improved in all survivors (n=16). There was no significant progression in regurgitation or transvalvular gradients.
CONCLUSIONS: Early results demonstrate that valve-in-valve transcatheter procedure is effective and safe alternative to redo surgery in selected patients with failed aortic or tricuspid bioprosthesis. Optimized positioning and deployment of the transcatheter valve are essential to the procedural success. This can be facilitated thanks to new emerging techniques for computer assistance based on preoperative CT images fusion and dynamic tracking on fluoroscopy.
Back to 2015 Annual Meeting Posters