Back to 2015 Annual Meeting Posters
A Shift in Cracking the Code: Change from CorMatrix ECM to Autologus Pericardium and CardioCel Usage to Repair Type III Mitral Valve Disease
Mohammed A. Kashem1, Thomas Kelley2, Priya Kothapalli1, Bill Moser1, Grayson Wheatley1, Yoshiya Toyoda1, Larry Kaiser1, Sloane Guy1.
1Temple University School of Medicine, Philadelphia, PA, USA, 2Dwight D. Eisenhower Army Medical Center, Fort Gordon, GA, USA.
OBJECTIVE: Earlier we adopted a simple technique to treat Carpentier Type III mitral insufficiency (MR) using routine anterior leaflet augmentation with CorMatrix Extracellular Matrix (ECM) in robotic mitral valve surgery, which showed variable results. We hypothesize autologus percardium use with glutaraldehyde and cardiocel may have better outcome in treating such diseases instead of using ECM.
METHODS: We performed endoscopic robotic mitral valve repair and AML augmentation in 24 patients and flexible bands (27.9±2.2 mm) were used. Simplified technique involved detachment of the AML at its base from commissure to commissure and placement of a large ECM patch into the defect. An annuloplasty sizer was used to select a band based on the inter-trigonal distance and was also used as an exact template to fashion the ECM patch. In addition, from March 2014, we have done 12 more MR repair with AML augmentation using autologous pericardium treated with glutaraldehyde and 4 more MR repair with AML using CardioCel™.
RESULTS: There were 3 groups, ECM (n=24), Autologous pericardium usage (n=13), and CardioCel™ (n=4). There were no significant differences in pre-op EF (ECM- 51±4%, AP- 40±16%, C- 43±19%; p=ns) and severe pre-op MR grade (ECM- 3.8±0.1, 3.8±0.5, 3.5±0.6; p=ns) in all cases. Table shows demographics and surgical data. There was no in-hospital and ≤30-days mortality in all groups. Post-op echo demonstrated no differences in EF in all groups (48% vs. 37% vs. 39%) and all patients were free from MR at the end of surgery on follow-up and at 1-month. In ECM group, there were four (4) reoperations compared to none (0) in other two groups treated with AP and CardioCel™ groups.
CONCLUSIONS: Simple technique of anterior leaflet augmentation with ECM had substantial re-operation rate compared to other techniques used in our center. More surgical cases and long-term follow ups are needed to measure the surgical outcome using newer technologies.
| CorMatrix | CardioCel | Autologous pericardial patch | |
| Mean age (years) | 59 ± 4 | 62 ± 16 | 67 ± 14 |
| Male | 52% | 66% | 50% |
| Weight (lbs) | 162 ± 38 | 188 ± 31 | 171 ± 42 |
| Pre-Op MR grade | 3.8 ± 0.1 | 3.5 ± 0.6 | 3.8 ± 0.5 |
| Pre-Op EF (%) | 51 ± 4 | 43 ± 19 | 40 ± 16 |
| Cross-Clamp time (min) | 88 ± 7 | 76 ± 8 | 84 ± 9 |
| LOS (days) | 7 ± 1 | 6 ± 1 | 7 ± 1 |
| 30-days mortality | none | none | none |
| Re-operation (≥ 30 days) | 4 | none | none |
Back to 2015 Annual Meeting Posters