Back to 2014 Annual Meeting Display Posters
Robotic Mitral Valve Replacement: Istanbul Experience
Sahin Senay, Ahmet U. Gullu, Muharrem Kocyigit, Aleks Degirmencioglu, Cem Alhan.
Acibadem University, School of Medicine, Istanbul, Turkey.
OBJECTIVE: In this video we present the details of our technique in robot assisted mitral valve replacement.
METHODS: A fifty two years old women with a body mass index of 36.6 kg/m2 underwent mitral valve replacement with a 29 mm bioprosthetic valve using the da Vinci robotic system (Intuitive Surgical, Sunnyvale, CA) through an incision of 3 cm.
RESULTS: The total operative time starting from anesthetic induction to skin closure was 230 minutes. Transesophageal echocardiography revealed competent prosthetic mitral valve without residual gradient. The patient was discharged from the hospital at fourth postoperative day without any complication.
CONCLUSIONS: Robot assisted mitral valve replacement may be performed as precise and fast as an open procedure. The described method may find broader application with the continuing evolution in this technology.
Back to 2014 Annual Meeting Display Posters