HEART LUXATION AFTER TOTALLY THORACOSCOPIC ABLATION.
Anna Witkowska, Radosław Smoczyński, Dominik Drobinski, Dariusz Kosior, Krzysztof Jaworski, Sławomir Sypuła, Monika Niewinska, Zygmunt Kalicinski, Bartlomiej Szafron, Jaroslaw Swistowski, Piotr Suwalski.
Central Clinical Hospital of the Ministry of Interior in Warsaw, Warsaw, Poland.
OBJECTIVE: Thoracoscopic access is gaining growing interest in cardiothoracic surgery. Despite it demands greater skills and attention, minimal injury correlates with lower complication rate and faster recovery of the patient. During thoracoscopic surgery it is necessary to create working space with insufflation of carbon dioxide (CO2). Here we describe a case of iatrogenic heart luxation caused by excessive CO2 tension during thoracoscopic ablation of atrial fibrillation (Afib).
METHODS: A 65-year old man with symptomatic resistant persistent AFib was referred to our institution for surgical ablation. His medical history involved kidney transplantation for end stage nephropathy, diabetes mellitus and stable coronary artery disease treated with bear metal stent implantation to left anterior descending coronary artery (LAD). Patient underwent totally thoracoscopic bilateral ablation of arrhythmia substrate with CO2 insufflation. As the first step from right port access isolation of right pulmonary veins (PVI) with connective lines and autonomic ganglia ablation was performed. As the second step from left port access left PVI with left atrial appendage stappling was performed.
RESULTS: Patient was extubated 6 hours after operation. Although stable condition mild hypotension requiring minor inotropic support with increasing renal markers and changes in electrocardiogram were observed. Based on unexpected postoperative chest X-rey examination suggesting dextrocardia in a patient with previous normocardia and inappropriate course we decided to perform computed tomography of the chest on the first postoperative day. It revealed distortion of the heart on the right side of the chest with stretch of the pulmonary trunk. Decision of immediate thoracoscopic revision was made. In right pleural cavity left ventricle and LAD were visible and tear in thin and flabby pericardium. Heart was replaced to pericardial sack. The patient was extubated immediately after reoperation. We observed rapid improvement in his condition with decrease in creatinine and troponin level. Patient in good condition, with stable sinus rhythm was discharged 10 days later.
CONCLUSIONS: Althoug totally thoracoscopic bilateral ablation of AFib is repeatable and safe procedure with promising results, this firstly described benign complication shows the need of closure of the pericardial sack, cautious use of CO2 and watchful following a patient after operation.