Back to ISMICS Main Site
 


Quick Links
   Home
Loading

 



Back to 2014 Annual Meeting Display Posters


Minimally Invasive Aortic Valve Replacement: Early Outcome And Results
udgeath dhir, MCh, Ramesh Kumar Bapana, MCh, Surinder Bazaz, MCh, Harpreet Wasir, MCh, Deepak Agarwal, MCh, Manisha Mishra, Naresh Trehan, MD.
Medanta Heart Institute, Gurgaon, India.

OBJECTIVE: In the era of catheter based aortic valve replacement, we intend to share our institutional experience of minimally invasive AVR trough right anterior Thoracotomy of 50 patients aged between 16 to 70 years .
METHODS: All the patients admitted between june 2012 to october 2013 for isolated aortic valve pathology were primarily evaluated for minimally invasive AVR. Our exclusion criteria were 1) small aortic root less than 19 mm .2) Aneurysmal dilatation of aorta and/or sinuses.3)inadequate femoral vessel size .4) ejection fraction less than 30%
Preoperative CT was done for evaluation of aortic anatomy .after evaluation standard protocol for anesthesia were followed with double lumen tube for intubation . TEE was placed in all patients . external defibrillation pads were placed . after draping femoral vessels exposed,and size of vessels assessed visually . once sure of the size,anterior thoracotomy done through 2nd intercostal space done with cutting of costochondral junction of the lower rib with clipping of Right internal mammary artery done . after femoral cannulation ,TEE guided retrograde coronary sinus cardioplegia catheter was inserted . Chitwood aortic clamp was used for cross clamping aorta . Anterograde blood cardioplegia with intermittent retrograde cardioplegia was used for myocardial protection . Standard interrupted pledgeted sutures used after proper sizing of the valve . costochondra junction was restored and intrapleural catheter placed for postoperative pain control .
RESULTS: All the 50 patients are on 100% follow up. average CPB time was 85 with ACC time of 63. average ventilation time was 5.5 hours . average drain was 210 ml. average hospital stay was 5 days .
in one patient ,with severe concentric hypertrophy ,median sternotomy was done while coming off CPB due to inability to defibrillate the heart. in one patient VATS was done for right pleural hematoma .
CONCLUSIONS: Minimally invasive is a safe procedure when performed after careful preoperative evaluation. no doubt the CPB time was more as compared to conventional AVR but the hospital stay and early recurrence are its major advantages .


Back to 2014 Annual Meeting Display Posters
 
© 2026 International Society for Minimally Invasive Cardiothoracic Surgery. All Rights Reserved. Read Privacy Policy.