Extrapleural Robot-Assisted Thymectomy With Contralateral Phrenic Nerve Protection
Faiz Y. Bhora, Muhammad Farhan Nadeem, Sadiq Rehmani, Michael Barsky, Jalal Abuhalimah, Cliff P. Connery, Scott Belsley.
St.Luke's-Roosevelt Hospital, New York, New York, NY, USA.

OBJECTIVE: A subset of thymic tumors are well-suited for resection by minimally invasive approaches. The robotic platform with distal articulation and magnification provides significant advantages in thymic operations. There remains oncern regarding visualization and protection of the contralateral phrenic nerve during transthoracic minimally invasive thymic surgery. We describe a technique where we perform a complete thymectomy using a minimally invasive transthoracic approach without the need for direct visualization of the contralateral phrenic nerve by keeping the medistinal pleura intact.
METHODS: A 32-years old patient was found to have a 5 x 3 cm complex anterior mediastinal mass. Per-cutaneous CT-guided biopsy was non-diagnostic. We performed a right VATS exploration and felt that this mass was completely resectable. Our operative technique for most mediastinal tumors includes a right-sided approach with identification of the confluence of the innominate vein and superior vena cava (SVC) as an important landmark. We performed a complete anterior mediastinal exenteration of all soft tissues anterior to the pericardium from the diaphragm up to the individual thymic horns which are divided as high as possible. The right phrenic nerve is directly visualized during the entire course of the operation. The left phrenic nerve, however, is not directly visualized. We utilize blunt dissection to lift the left mediastinal pleura off the mediastinum, with care taken to leave the pleura intact. This technique allows us to lift the phrenic nerve off the mediastinum with no risk of injury to the nerve during the course of mediastinal dissection. If there is an inadvertent entry into the pleura, we are also able to directly visualize the nerve by advancement of the camera into the left pleural cavity.
RESULTS: The video highlights the technique that we have described in our abstract.
CONCLUSIONS: Extrapleural robot-assisted thymectomy is a straight forward technique that allows protection of the contralateral phrenic nerve during minimally invasive thymic surgery without need for direct visualization of the nerve. In particular, it avoids opening the contralateral pleural cavity and risk of post-operative pleural effusion or pneumothorax.