Back to 2014 Annual Meeting Display Posters
Collared Graft for Hybrid Repair of Extensive Thoracic Aortic Aneurysm
Kenji Aoki, Takeshi Okamoto, Hiroki Sato, Osamu Namura, Kazuhiko Hanzawa, Masanori Tsuchida.
Niigata University, Niigata, Japan.
OBJECTIVE: Hybrid procedure of graft replacement with elephant trunk (ET) and endovascular repair with stent graft has been an optimal treatment for extensive thoracic aortic aneurysm (eTAA). However, such a hybrid repair (HR) is limited when the aneurysm is extended to the ascending aorta. Size discrepancy in the anastomotic site becomes a great problem. In Japan, the maximum diameter of commercially available grafts for aortic reconstruction is 30 mm. When the aorta is 50 mm or more, the difference in size cannot be resolved by simple plication of the aorta. We developed a new graft to correct the mismatch.
METHODS: We created a collared graft for HR. It has a donut of Dacron tube graft. The donut functions as a collar to correct the mismatch in the anastomotic site.
RESULTS: We used a collared graft for HR of eTAA. [Case] An 80 years-old woman was referred to our department for asymptomatic aneurysm of the thoracic aorta. Computed tomography (CT) showed an extensive aneurysm of ascending, arch and descending thoracic aorta extending to the diaphragm level. The aneurysm was over 70 mm at its arch and descending segment. The ascending aorta was 62mm. To complete an anastomosis in the ascending aorta, a collared graft was made by a combination of 30-mm branched aortic graft and 12-mm straight graft. The collar was about 60 mm in diameter. Under cardiopulmonary bypass, the collared graft with ET was anastomosed to the aneurysmal ascending aorta with continuous suture of 4-0 polypropylene. After arch branches were reconstructed, the residual aneurysm was excluded with 36mm and 34 mm stent grafts by connecting to ET. She experienced consumption coagulopathy early after surgery and tolerated by transfusion. Postoperative CT showed complete exclusion of the aneurysm.
CONCLUSIONS: A collared graft can be an option to complete HR for extensive aneurysm including ascending aorta.
Back to 2014 Annual Meeting Display Posters