Back to 2014 Annual Meeting Display Posters
Improved Technique for Totally Endoscopic Antegrade Cardioplegia Delivery in Robotic Surgery
Louis A. Brunsting, III, MD, Robert L. Reed, CCP, Charles M. Tyndal, CCP.
University of Alabama in Birmingham, Birmingham, AL, USA.
OBJECTIVE: Delivery of antegrade cardioplegia in totally endoscopic, robotic cardiac surgery has been characterized by compromise between hydrodynamics (cardioplegia delivery flow rate and adequate venting) and invasiveness (a larger cannula needs a bigger hole). We hypothesized a pediatric ECMO cannula would provide comparable hydrodynamics to open cardioplegia cannulae, with a minimal additional incision.
METHODS: An 8 Fr. pediatric arterial ECMO cannula was adapted for transthoracic placement into the aortic root using robotically controlled Seldinger technique. Cardioplegia delivery flow rates and line pressures were measured. The attached video completely describes the procedure.
RESULTS: In 17 patients, the described technique resulted in antegrade cardioplegia flow rates (319.0+17.4 ml/min) and line pressures (200.7+22.3 mmHg) similar to those experienced in open chest procedures (319.2+23.9 ml/min and 199.5+45.5 mmHg, respectively). Good aortic venting was accomplished, with minimal intracardiac air on transesophageal echocardiography and no instance of transient ST elevation suggestive of intracoronary air embolism. The additional incision ranged from 3 to 5 mm in length.
CONCLUSIONS: In totally endoscopic robotic cardiac surgery, the technique demonstrated in the attached video resulted in hydrodynamics comparable to open chest cardioplegia delivery, with a minimal additional incision.
Back to 2014 Annual Meeting Display Posters