Facile Implantation of Neochordae for Complex Mitral Valve Repair with the Minimally Invasive Right Thoracotomy Approach: 2 Year Follow-up
Michael J. del Rio, Steven Jin, Cynthia Jovanov, Houshang Karimi.
Riverside Community Hospital, Riverside, CA, USA.

OBJECTIVE: To evaluate the efficacy and durability of titanium suture fasteners for facilitation of neochordal implantation for Mitral Valve repair in the minimally invasive approach
METHODS: 2 patients with Severe Complex Mitral Valve Regurgitation were implanted with neochordae utilizing a titanium suture fastener on 2-0 polyester suture along with other repair techniques in a minimally invasive right minithoracotomy approach.
The first patient was a 47 year old male who had severe cardiomyopathy with a 20 % ejection fraction and severe mitral valve regurgitation. At surgery, he underwent repair with a posteromedial commisuroplasty and implantation of a # 28 annuloplasty ring as well as neochordal implantation at A2 using the titanium fastener and 2-0 polyester suture.
The second patient was a 46 year old male with Severe Mitral Valve Regurgitation due to Barlow's Pathology. At surgery, he underwent implantation of a # 32 annuloplasty ring and formation of a revised line of apposition along the posterior leaflet by neochordal implantation along a created rolled edge of the redundant posterior leaflet at P1,P2 and P3 using the titanium suture fastener onto 2-0 polyester suture.
RESULTS: Both patients were discharged on post operative day
# 5 with no significant Mitral Valve Regurgitation.
Both patients returned to their blue collar jobs within 1 month of surgery. One and Two year followup of these patients by echocardiogram have shown intact Mitral Valve repairs with no significant Regurgitation.
CONCLUSIONS: The titanium suture fasteners feature the unique capability to secure knots without slippage at precise designated lengths. The implantation of these chordae took minutes and lengths were easily measured. The durability of the neochordae has now been demonstrated at 2 Years followup. This is the first report to show the use of this type of device to facillitate neochordal implantation and now this is the first report that shows its long term efficacy. This preliminary data further reinforces the need for a larger multicenter study.