Back to ISMICS Main Site
 


Quick Links
   Home
Loading

 



Back to 2014 Annual Meeting Display Posters


Right Anterior MInithoracotomy AVR with fast deployment Edwards Intuity Valve System
Marco Solinas, Francesca Chiaramonti, Federica Marchi, Pier Andrea Farneti, Filippo Santarelli, Enkel Kallushi, Tommaso Gasbarri, Giacomo Bianchi, Sergio Berti, Paolo Antonio Del Sarto, Mattia Glauber.
Heart Hospital G.Pasquinucci FTGM, Massa, Italy.

OBJECTIVE: In our centre the approach of choice for an isolated aortic valve replacement (AVR) is the right anterior minithoracotomy (RT). In this video we want to show a minimally invasive AVR through a RT using a new fast-deployment bioprosthesis: the Edwards Intuity Valve System.
METHODS: A 6-7 cm incision is performed in the second intercostal space at the sternal edge. A soft tissue retraction is made to obtain a good exposure. Usually the aortic cannulation is made directly in the ascending aorta and the venous return is obtained with a multistage femoral cannula inserted percutaneously in the groing. The cardioplegia is administred antegradly in the aortic root. The aorta is directly cross-clamped. A standard aortotomy is performed. The three native valve leaflets are excised and the aortic annulus is completely decalcified. Three 2-0 ethibond sutures are placed through the nadir of the aortic annulus. The sizing is performed and the right prosthesis is selected. The three sutures are passed on the prosthesis ring at the level of the three black marks. By using this sutures as guiding sutures, the valve with its delivery system are lowered into the annulus under direct vision. The correct position is accurately checked. The sutures are put tense. The balloon catheter is inflated to deploy the stent frame. The delivery system and valve holder are removed as a single unit. The three sutures are tied.
RESULTS: Between June 2012 and December 2013, 47 patients with symptomatic aortic stenosis underwent AVR with EDWARDS INTUITY Valve System. Of these, 36 patients underwent isolated AVR. After firsts cases performed through a median full sternotomy, 31 (66% of all patients and 86% of isolate aortic valve disease patients) patients received a minimally invasive approach (MIA): 21(68%) patients through an upper J-type ministernotomy and 10 (32%) patients through a RT. In RT group implantation success was 100% (10/10) without any complication releated to the approach.
CONCLUSIONS: AVR with EDWARDS INTUITY Valve System using a RT is a safe and reproducible procedure in experienced centre. This sutureless bioprosthesis simplifying the valve implantation can be useful to increase MIA for AVR.

Download ePoster


Back to 2014 Annual Meeting Display Posters
 
© 2026 International Society for Minimally Invasive Cardiothoracic Surgery. All Rights Reserved. Read Privacy Policy.