Back to 2014 Annual Meeting Display Posters
Aortic Valve and Ascending Aorta Replacement Through a J Mini-Sternotomy
Marco Di Eusanio, Giacomo Murana, Mariano Cefarelli, Paolo Berretta, Sebastiano Castrovinci, Gianluca Folesani, Roberto Di Bartolomeo.
Ospedale S.Orsola-Malpighi, Bologna, Italy.
OBJECTIVE: Mini-sternotomy is infrequently used during combined aortic valve and ascending aorta interventions. In fact, this adds complexity when compared to a standard median sternotomy approach. This video shows in details a simplified technique for aortic valve and ascending aorta replacement through a J-ministernotomy.
METHODS: The patient was a 51-year-old female with a 47 mm ascending aorta aneurysm and a bicuspid aortic valve with severe aortic stenosis/insufficiency. Through a 5 cm skin incision and mini-sternotomy, the patient was centrally cannulated. The ascending aorta was replaced with a 24 mm Dacron graft and the aortic valve with a 22mm mechanical valve. The total cross-clamp time was 68 minutes.
RESULTS: The patient was uneventfully discharged on post-operative day 6, with no need for red blood cell transfusion. Pre-discharge echocardiogram and angio CT scan showed a satisfactory result.
CONCLUSIONS: Ascending aorta and aortic valve replacement can be safely performed through a mini-sternotomy with acceptable ischemic times. This approach requires minor modifications in standard techniques that can be readily learned by most surgeons having experience with conventional ascending aortic and valvular surgery.
Back to 2014 Annual Meeting Display Posters