Robotic surgery will be truly minimally invasive cardiac surgery in the future
Changqing Gao.
PLA General Hospital, Beijing, China.

OBJECTIVE: To summarize the experience of 650 cases of various kind of robotic heart surgery performed by a single surgeon in single center.
METHODS: Six hundreds and fifty patients underwent robotic cardiac surgery from 2007 to 2013 in PLA General Hospital. There were 357 male and 293 female with a median age of 52.9±23.7 (11 to 80) years old. Left port approaches were used in totally endoscopic coronary bypass (TECAB) graft on beating heart (n=100) and direct coronary bypass grafting with minithorocotomy (MIDCAB) on beating heart (n=130). Right port approaches were used in mitral valve repair (n=100), mitral valve replacement (n=45), atrial myxoma resection (n=45), atrial septal defect repair on arrest (n=54) or on beating (n=121) heart, ventricular septal defect repair (n=20), hybrid revascularization (n=35), and other robotic cardiac surgery (n=35). Cardiopulmonary bypass (CPB) was established through peripheral vascular cannulation. The Chitwood clamp was used to occlusion the ascending aorta. All the robotic coronary bypass graft surgeries were completed without CPB.
RESULTS: No operative mortality or serious surgical complications were observed. For patients with atrial or ventricular septal defect, no residual shunt was detected at postoperative echocardiography. No patient required reoperation for recurrence in the follow-up of (31±14) months. Robotic mitral valve plasty included quadrangular resections, sliding-plasties, neochord insertion, edge to edge and annuloplasties. Postoperative echocardiograms showed that the patients had no mitral regurgitation (98%) or trace mitral regurgitation. The mean graft flow was (35.8±20.0) ml/min in TECAB group. And all the patients accepted coronary angiography or CTA scan follow-up with 98.1% graft patency. One graft occlusion was found in 1 year postoperatively. And no more graft occlusion was found at 3 to 5 years. In MIDCAB group, single or double grafts were completed in “Y” type or sequence manner. The mean graft flow was (26.9±12.8)ml/min. Thirty-five patients with multiple vessels diseases had off-pump robotic bypass surgery and stent placement using a staged approach without complications.
CONCLUSIONS: Our study shows that robotic cardiac surgery is safe procedure in selected patients, and we believe that the robotic surgery will be truly minimally invasive cardiac surgery in the future.

Download ePoster


Back to 2014 Annual Meeting Display Posters
 
© 2026 International Society for Minimally Invasive Cardiothoracic Surgery. All Rights Reserved. Read Privacy Policy.