Sutureless aortic valve replacement with minimal invasive access and minimised perfusion circuit: a TAVI alternative approach?
Carlo Savini, Giuliano Jafrancesco, Jacopo Alfonsi, Sofia Martin Suarez, Giacomo Murana, Irene Dotti, Davide Zardin, Roberto Di Bartolomeo.
Ospedale S. orsola, bologna, Italy.

OBJECTIVE: Conventional cardiac surgery in the last years progressed in three independent ways to improve its results: Valve Prosthesis improvement as design and deployment (Sutureless prosthesis, SU-AVR); Minimised Cardio-Pulmonary Bypass (MCPB) to reduce the systemic inflammatory response syndrome and Minimal Invasive surgical Cardiac approach (MICS). The aim of this study is to evaluate the outcomes of the combination of these issues for Aortic Valve Replacement (AVR) in high-risk patients.
METHODS: We reviewed 10 SU-AVR performed in a population affected by severe aortic stenosis with average age of 78.8± 8.7 from January 2013 to November 2013. The mean STS score (%) was 9.2±6.5. The mean basal glomerular filtration rate was 62.5±27.9 mL/min with baseline serum creatinine of 1.1±0.5 mg/dl. The end-points were defined as hospital mortality, perioperative myocardial infarction, cerebrovascular events and surgical procedure related complications. Furthermore, the renal function was investigated by glomerular filtration rate and serum creatinine level before surgery and at 1st, 3rd, 5th, postoperative day.
RESULTS: No hospital mortality was observed. The mean hospital stay was 8.6 ± 1.2 days. No patient had major adverse events. Postoperative renal function curve reveals no increase of clinical/subclinical serum creatinine. The mean serum creatinine level (g/dl) and glomerular filtration rate (mL/min) were 1.1±0.5, 1.1±0.6, 0.97±0.46, 0.8±0.45 and 54.8, 54.1, 56.9 at 1st, 3rd, 5th postoperative day, respectively. The pre-discharge echocardiogram has shown satisfactory results with 1.6±0.5 cm² of effective orifice area, 14.8±4.2 mmHg of mean aortic gradient
CONCLUSIONS: Surgical aortic valve replacement is still the treatment of choice in patient with aortic stenosis. To improve the advantages of conventional surgery for high-risk patients, we combined in a single approach the innovations available for AVR as SU-AVR, MCPB and MICS. To better analyse the quality of this idea, we observed the incidence of postoperative major events and some indicators of a good postoperative performance as the variation of serum creatinine, which has been demonstrated to be independently associated with 30-day all-cause mortality after cardiac surgery. Finally, this preliminary experience shows that an optimized approach for high-risk patients, including SU-AVR, MPCS and MICS, is safe and effective.