The transaortic approach for transcatheter aortic valve implantation: A valid alternative. A single centre experience.
R Haris Bilal, Jessica Maycock, Mahvash Zaman, S Hampshaw, D Fraser, Ragheb Hasan, Vaikom Mahadevan.
Manchster Royal Infirmary, Manchester, United Kingdom.

OBJECTIVE: Transaortic (TAo) route for transcatheter aortic valve implantation (TAVI) is a novel approach. It is a feasible alternative for patients with unfavourable transfemoral (TF) access. We evaluated our early experience and quality of life improvement following TAo-TAVI approach using Edwards Sapien platform (Edwards Lifescience, Irvine, CA, USA).
METHODS:
92 patients between Feb 2009- Jan 2014 underwent TAVI. Tao-TAVI was performed in 6 patients with unfavourable access for TF approach. Aortic valve, root and annular size were carefully assessed by computed tomography (CT Angiography), transoesophageal echocardiography (TOE) and coronary angiography. The aorta was exposed through a hemisternotomy.
Early results and functional improvement was assessed. In addition pain assessment (NRS-11) and quality of life evaluation was performed via SF-36 and SF-12v2.
RESULTS: Mean age was 79.1 ± 5 year. Mean logistic Euroscore 18.2 ± 10. All patients had grade III-IV descending aortic calcification. Mean preoperative valve area and mean gradient was 0.7 ± 0.4 cm2 and 70 ± 26.2 mm of Hg respectively. Mean annular diameter was 2.4 ± 0.2 cm2. Edwards Sapien XT was used in all cases.
Hemisternotomy was performed in all patients.
Mean size of implanted device was 2.6 ± 0.2cm2. Device was successfully implanted in all cases.
Mild-moderate para valvular leak was observed in one patient (6%). There was no in-hospital mortality or stroke. Mean hospital stay was 11.6 ± 5.1 days. All patients remain well on follow-up.
There was marked improvement in functional status, New York Heart Association (NYHA) to 1.7 ± 1.2 vs. 3.4 ± 1.1 preprocedural (p=0.02). In addition quality of life, SF-36 evaluation showed an improvement of 56.2 vs.24.8 preprocedural (p<0.01). Mean pain score was 4.1 and 3.8 on day 1 and 4 respectively (NRS-11).
CONCLUSIONS:
The TAo approach for Sapien XT is a clinically safe approach with satisfactory early results in our experience and provides an alternative to TF with difficult peripheral access.