Collaborative Lead Management Increases Volume and Case Complexity
Rebekah Macfie, MSIV, Anil Gehi, Eugene Chung, Paul Mounsey, Andy C. Kiser.
University of North Carolina at Chapel Hill, Chapel Hill, NC, USA.
Objectives: This study examines a novel collaborative approach to cardiovascular implantable electronic device (CIED) lead extraction in which the cardiac surgeon and electrophysiologist (EP) work together to extract and re-implant leads. We compared this new protocol with EP-only and surgeon-only extraction.
Methods: Lead extraction records from 2007- 2013 were reviewed. In the standard and surgeon-only approaches the respective EP or surgeon performs the entire procedure. In the collaborative approach the cardiac surgeon does the lead extraction and the EP completes the re-implantation; both physicians are engaged for the entire case.
Results: Forty-nine patients underwent collaborative extraction, 34 underwent standard EP-only extraction and 20 patients underwent surgeon-only extraction. In the hybrid approach infection was the indication for extraction in 20% of cases (10/49); in the surgeon-only approach infection was the indication for extraction in 85% of the cases (17/20); in the EP-only cases infection was the indication in 15% of the extractions. For cases with a surgeon involved (hybrid and EP-only) there were significantly more leads removed due to infection than in EP-only cases (p=0.0099). There was no significant difference in the average number of leads extracted in the EP vs. collaborative techniques (1.26 vs 1.48 p=0.11). There were, however, a significantly greater average number of leads extracted in the surgeon-only group (2.315) as compared to the collaborative (p<0.05) and EP only group (p<0.05). Procedures with a surgeon involved (collaborative and surgeon-only) were significantly more likely to use the laser than EP-only cases (p <0.005) suggesting increased complexity of these cases. There was a trend toward decreased post-operative complications in patients undergoing hybrid extractions. The institution of hybrid lead management has contributed to four-fold case growth in lead extractions and a three-fold increase in device reimplantations since the initiation of the collaborative technique in 2011 (Chart 1).
Conclusions: This review suggests that a collaborative approach to intravenous CIED lead management allows for safe management of complicated lead extraction can provide excellent patient outcomes and practice growth.